tecnica:motori:honda_ntv650_wiring_diagram
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| tecnica:motori:honda_ntv650_wiring_diagram [2025/10/21 10:24] – [Harness wires gauge] niccolo | tecnica:motori:honda_ntv650_wiring_diagram [2025/10/24 17:52] (current) – [Honda NTV650 Revere - Wiring diagram] niccolo | ||
|---|---|---|---|
| Line 3: | Line 3: | ||
| Here it is the **wiring diagram drawn in color**. It was derived by me from a black and white printed diagram from Honda. Inspecting the original drawing I spotted two erros: there were two missing joints. Both were in the main harness, one on the green wires and the other in the white/green wires. | Here it is the **wiring diagram drawn in color**. It was derived by me from a black and white printed diagram from Honda. Inspecting the original drawing I spotted two erros: there were two missing joints. Both were in the main harness, one on the green wires and the other in the white/green wires. | ||
| - | {{.: | + | {{.: |
| - | Here it is the the PDF version: **{{.: | + | Here it is the the PDF version: **{{.: |
| ===== Headlight wiring ===== | ===== Headlight wiring ===== | ||
| Line 23: | Line 23: | ||
| The outer diameter refers to the overall cable, including the insulator. The AWG gauge is calculated measuring the diameter of the single strand and calculating the overall cross-sectional area; then the nearest value is looked into the [[wp> | The outer diameter refers to the overall cable, including the insulator. The AWG gauge is calculated measuring the diameter of the single strand and calculating the overall cross-sectional area; then the nearest value is looked into the [[wp> | ||
| - | **NOTICE**: The **19 AWG 30/34** notation means that there are 30 strands, each strand is an AWG #34 wire (0.160 mm diameter), the overall cross-section | + | **NOTICE**: The **19 AWG 30/34** notation means that there are 30 strands, each strand is an AWG #34 wire (0.160 mm diameter), the overall cross-sectional |
| **NOTICE**: The **ampacity** reported in the table is the maximum electrical current in amperes that the conductor can carry for **2 meters**, mantaining the **voltage drop below 2%**. The formulas for calculating the voltage drop for a copper conductor (coefficient ρ = 1.68*10^-8 Ωm) are: | **NOTICE**: The **ampacity** reported in the table is the maximum electrical current in amperes that the conductor can carry for **2 meters**, mantaining the **voltage drop below 2%**. The formulas for calculating the voltage drop for a copper conductor (coefficient ρ = 1.68*10^-8 Ωm) are: | ||
| Line 76: | Line 76: | ||
| {{.: | {{.: | ||
| - | You will hear the noise from the working pump. Ance the carburetors are full, the pump will stop. | + | You will hear the noise from the working pump. Once the carburetors are full, the pump will stop. |
| ===== Connectors wires color ===== | ===== Connectors wires color ===== | ||
tecnica/motori/honda_ntv650_wiring_diagram.1761035075.txt.gz · Last modified: by niccolo